最先進的光程檢測技術
不同于傳統的紫外-可見光方法僅依賴於一個絕對吸光度值,DS-11採用最先進的動態光程斜率光譜技術,利用多點數據
(吸光度vs.路徑長度)檢測斜率值來定量樣品濃度。
SmartPath 斜率分光技術通過無可比擬的光程掃描性能,快速建立吸光度vs光程線性圖線,通過圖線斜率快速精確的測
量樣品濃度。
斜率分光技術獲得2008年R&D100創新大獎,是目前最好的動態可變光程濃度檢測技術,正在成為分光光度計的最新技術標準。Slope技術可檢測更高的濃度範圍,無需稀釋,無需基線校準。
SmartPathTM技術無需拉伸樣品即可自動調節光程,避免樣品柱坍塌問題,具備極佳的核酸和蛋白檢測功能。
原因一:
依據著名的郎伯.比爾定律(紫外分光光度計理論基礎),從圖示可見從0.8mm光程開始,測量結果波動很大,因此DS-
11採用了最為穩定的0.5mm光程作為上限,保證極高的測量精度和穩定性。
原因二:
A 0.5mm Path length measurement will give a more accurate measurement that the same sample
measured in a 1.0mm path length.
There are multiple reasons for this, but I think the simplest explanation is as follows:
The measurement system noise can lead to less reproducible measurements.
A disadvantage of shorter path length instruments is seen when measuring low concentration samples -
at the low Absorbance being measured the background noise becomes a higher proportion of the
measured signal resulting in less accurate measurements
For example: if we measure a 10ng/μl DNA sample in a 10mm pathlength cuvette the Absorbance at
260nm is: 10/50 = 0.2 Absorbance
The same sample measured using a micro-volume instrument with a 1mm pathlength the Absorbance
would be: (10/50)/10 = 0.02 Absorbance
Assuming that the inherent noise of both instruments is the same, 0.002A, this accounts for a 1% error
on the instrument with a 10mm path length cuvette but a 10% error on the 1mm path length micro-
volume instruments.
This % error increases as the concentration decreases. and also explains why an instrument with a
10mm path length cuvette has a lower detection limit (0.5ng/μl) in comparison to a micro-volume
instrument (reported as 2-5 ng/μl). This confirms that a 10mm path length cuvette provides a lower
detection limit than a cuvette with a 0.5mm path length.
To summarise:
1.0mm Pathlength: 10 % Error
10mm Pathlength: 1% Error
One can therefore assume hat the error obtained with a 0.5mm path length is somewhere between 10%
& 1.0%
通用-超微量模式
最少樣品體積:0.5 µl
樣品數量:1
路徑長度:0.5 mm (auto ranging to 0.03 mm)
光源:Pulsed Xenon flash lamp
探測器類型:2048 element CCD
波長範圍:190-840 nm
波長準確度:0.5 nm
吸光度精密率:0.002 AU (0.5 mm path), or 1%, whichever is greater
吸光度準確度:1.5% at 0.75 AU at 260 nm
吸光度範圍值:0.04 – 750 (1 cm equivalent)
檢測極限:0.04 mg/ml BSA; 0.75 ng/µl dsDNA
最高濃度:1125 mg/ml BSA; 37500 ng/µl dsDNA
測量時間:2秒
Footprint:20 cm X 33 cm
重量:2 kg
樣品基座材料:303 stainless steel and sapphire window
樣品頂臂材料:303 stainless steel and quartz fiber
工作電壓:12 VDC
工作功耗:10 W; (max 45 W)
操作系統:板載控制器(無需PC),介面為Custom Android OS
認證:CE, UL/CSA and FCC
產地:美國
控制系統
操作系統:AndroidTM OS
CPU:TI OMAP ARM Processor
顯示器 :1280 X 800 high definition color display
內存硬碟:8GB flash drive
傳輸:3 USB ports for printer, barcode reader and USB drive
網路:Ethernet and Wi-Fi
產品特色
■ 具備目前最高的濃度檢測範圍
BSA偵測範圍是0.04~1125mg/ml,雙股DNA是0.75~37500 ng/ul。
■ 具備目前最精確的檢測能力,具有獨特SmartPathTM的技術,偵測樣品時可自動判定適當的路徑長度。
■ 操作簡便,操作步驟相當簡單,只要滴入樣品與測量即可。測量僅需四秒,大量節省操作時間。並具備自動檢測模式,
■ 極高的測量重複性,終生無需校準。
目前常用的超微量檢測方法:傳統懸臂式和微量比色杯式。傳統懸臂式可自動變光程但每半年需要一次校準,既影響了
測量精度,也增加了使用成本;微量比色杯式(或固定光程式)需要更換蓋子來變換光程,需預估樣品的濃度範圍,再
選定適合的蓋子,容易導致較大誤差。DS-11完美解決了上述問題,因此DS-11是唯一一款真正的全自動可變光程且
無需校準的超微量分光光度計。
■ 全波長分析!!
樣品檢測體積僅需0.5~1.0μl。波長範圍從190~840nm,可提供使用者有不同的選擇。
■ DS11具有相當簡便的操作軟體!!
僅需手指觸碰打開程式。
不需關閉程式就可以切換程式 。
可設立密碼以保護帳戶。
可設定新的偵測模式。
可無限添加偵測的方法
所有的資料都會自動儲存並且方便輸出。
■ AndroidTM 獨特介面
儀器內建 AndroidTM 系統,透過觸控螢幕操作。
具高解析度與全彩的螢幕呈現結果。寬頻螢幕無死角。即使操作者戴手套也可以操作。
DS-11內建Wifi與3個USB孔槽,可用與傳輸資料。可連接印表機,直接列印報告。